Victron Lynx Power In
The Lynx Power In contains a positive and negative busbar with 4 connections for batteries, loads or chargers and a ground connection. It is part of the Lynx Distribution system.
- The Lynx Distributor contains a positive and a negative busbar. The positive busbar has four fuse protected connections with fuse monitoring. The negative busbar has four connections and a ground connection. It is part of the Lynx Distribution system. The Lynx Distributor has a power LED and four fuse status indication LEDs. If connected to a Lynx Smart BMS, up to 4 Lynx Distributors can send fuse status information to the Lynx Smart BMS. This feature is not available when connected to a Lynx Shunt VE.Can.
- The Lynx Distributor contains a positive and a negative busbar. The positive busbar has four fuse protected connections with fuse monitoring. The negative busbar has four connections and a ground connection. It is part of the Lynx Distribution system. The Lynx Distributor has a power LED and four fuse status indication LEDs. If connected to a Lynx Smart BMS, up to 4 Lynx Distributors can send fuse status information to the Lynx Smart BMS. This feature is not available when connected to a Lynx Shunt VE.Can.
- If the Lynx Distributor is connected to a Lynx Smart BMS it can be monitored and setup with the VictronConnect App.
- Up to 4 connected Lynx Distributors can be monitored with a GX device if they are connected to a Lynx Smart BMS. The GX device can be connected to the VRM portal allowing for remote monitoring
The Lynx Distribution System
The Lynx Distribution System is a modular busbar system that incorporates DC connections, distribution, fusing, battery monitoring and/or Lithium battery management. For more information also see the DC Distribution Systems product page.
The Lynx Distribution System consist of the following parts:
- Lynx Power In - A positive and negative busbar with 4 connections for batteries or DC equipment.
- Lynx Distributor - A positive and negative busbar with 4 fused connections for batteries or DC equipment together with fuse monitoring.
- Lynx Shunt VE.Can - A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. It has VE.Can communication for monitoring and setup with a GX device.
- Lynx Smart BMS - For use together with Victron Energy Smart Lithium batteries. It contains a positive busbar with a contactor that is driven by a battery management system (BMS) and a negative busbar with a shunt for battery monitoring. It has Bluetooth communication for monitoring and setup via the VictronConnect App and VE.Can communication for monitoring with a GX device and the VRM portal.
| Part Number | VIC-LYN020102000 |
|---|---|
| Voltage range | 9 - 60Vdc |
| Current rating | 1000A |
| Busbar | M8 |
| Busbar material | Tinned Copper |
| Enclosure material | ABS |
| Weight | 2.1 kg |
| H x L x W | 290 x 170 x 80 mm |
| Operating temperature range | -40°C to +60° |
| Protection class | IP22 |
| Part Number |
|---|
| VIC-LYN020102000 |